UPS Selection

Understanding the Vertiv Liebert GXT4 UPS Series

Introduction The Vertiv Liebert GXT4 family is an established online UPS platform designed for applications requiring continuous power protection. Power Icon’s current catalogue includes GXT4 models ranging from 500VA to 3000VA. Available Power Icon Models Important Compatibility Consideration GXT4 models have different input/output configurations. In particular, the listed GXT4-RT120 models are designed around 120V configurations, while the GXT4-3000RT208 is a 208V configuration. Electrical compatibility must therefore be confirmed before deployment. Power Icon Availability These units are pre-owned, refurbished and tested before delivery. New replacement batteries are available separately.

UPS Selection

Understanding the Vertiv Liebert GXT5 UPS Series

Introduction The Vertiv Liebert GXT5 family includes online double-conversion UPS systems designed for applications requiring protected and continuous power. Power Icon’s current catalogue includes GXT5 models from 750VA through 3000VA. Available Power Icon Models GXT5-750IRT2UXLE — 750VA / 750W GXT5-1000IRT2UXLE — 1000VA / 1000W GXT5-1500IRT2UXLE — 1500VA / 1500W GXT5-2000IRT2UXLE — 2000VA / 2000W GXT5-3000IRT2UXLE — 3000VA / 3000W Key Characteristics The GXT5 platform includes features such as: Power Icon Availability Our GXT5 units are pre-owned equipment refurbished and tested by Power Icon. New replacement batteries are available separately.

UPS Maintenance

How to Maintain a UPS System

Introduction A UPS should not simply be installed and forgotten. Regular inspection and maintenance can help identify issues before they become operational problems. What Should Be Checked? Depending on the UPS: Battery Maintenance UPS batteries have a finite service life and may eventually require replacement. Keep Records Maintain records of: Final takeaway Regular attention to UPS condition can help improve operational preparedness.

Electrical & Site Readiness

Why Electrical Site Assessment Matters Before Equipment Installation

Introduction Installing equipment without first understanding the site’s electrical conditions can create unnecessary problems. What Should Be Assessed? A site assessment can consider: Why It Matters Proper preparation can help identify electrical requirements before equipment installation begins. Power Icon’s Approach Power Icon conducts electrical requirements and site assessments for applications where equipment power requirements need to be understood before installation. Final takeaway Good site preparation is part of good equipment deployment.

Power Protection

What Is AVR and When Do You Need It?

Introduction Automatic Voltage Regulation, commonly referred to as AVR, is used to regulate variations in electrical voltage. Why Voltage Regulation Matters Electrical equipment can be affected by voltage that is consistently too high, too low or unstable. Voltage regulation can help maintain a more suitable supply for connected equipment. AVR vs UPS An AVR primarily addresses voltage regulation. A UPS can provide additional functions including backup power and, depending on architecture, power conditioning. Choosing Between Them The right solution depends on: Final takeaway AVR and UPS systems serve related but different purposes and can sometimes be used as part of a broader protection strategy.

UPS Selection

How Long Will a UPS Run During a Power Outage?

Introduction UPS runtime is not a single fixed number. The amount of time a UPS can operate during an outage depends on several variables. The Main Factors Connected Load Higher load generally means shorter runtime. Battery Capacity Larger battery configurations can provide longer runtime. Battery Condition Older or degraded batteries may provide less runtime than new batteries. External Battery Cabinets Compatible external battery cabinets can significantly extend runtime. Example A GXT5 system can have substantially different runtime at 50% load compared with 100% load. Therefore, asking “How many minutes does this UPS provide?” without specifying the load can be misleading. Final takeaway Provide your expected load when asking Power Icon for a runtime recommendation.

UPS Basics

What Is Online Double-Conversion UPS Technology?

Introduction Online double-conversion is a UPS architecture designed for continuous power conditioning and protection. How It Works The incoming AC power is converted to DC and then converted back to AC before being delivered to the connected load. This creates a controlled output supply for connected equipment. Why It Matters Online double-conversion UPS systems can be useful for applications where: Where Are They Used? Common application areas include: Final takeaway The UPS architecture should match the importance and sensitivity of the connected equipment.

UPS Selection

Refurbished UPS vs. New UPS: What Should You Choose?

Introduction Buying a UPS doesn’t always mean buying a brand-new unit. Refurbished UPS equipment can provide another option for businesses that need established power-protection hardware while managing equipment costs. What Is a Refurbished UPS? A refurbished UPS is pre-owned equipment that has undergone inspection, servicing and testing before being offered for reuse. Why Consider Refurbished Equipment? Potential advantages include: What Should You Check? Ask about: Power Icon’s Approach Power Icon supplies pre-owned UPS equipment that is refurbished and tested before delivery. New replacement batteries are available separately.

UPS Maintenance

UPS Batteries: What You Should Know Before Buying

Introduction The battery system is one of the most important components of a UPS. A UPS can be electrically functional while still requiring battery replacement because batteries naturally age over time. Why Batteries Matter Battery condition affects: New Batteries for Refurbished UPS Systems Power Icon supplies refurbished UPS units separately from replacement batteries. New batteries can be provided separately based on the specific UPS model and required configuration. Why Battery Pricing Varies Battery pricing can change according to: Final takeaway Always confirm the battery configuration when purchasing a refurbished UPS.

UPS Basics

How to Choose the Right UPS Capacity for Your Equipment

Introduction UPS capacity is commonly expressed in VA and watts. Choosing a UPS solely because its VA rating appears sufficient can be a mistake. The connected load and required operating margin also matter. Start With Your Load Identify the equipment that needs protection and determine its expected power consumption. Consider VA and Watts VA represents apparent power while watts represent real power consumption. The relationship between the two is affected by power factor. Allow Appropriate Capacity Avoid selecting a UPS that operates permanently at its maximum capacity. A suitable operating margin can provide additional flexibility for changing loads. Consider Runtime If backup runtime matters, battery capacity and external battery options should also be evaluated. Final takeaway Tell Power Icon your equipment and load requirements rather than selecting a model based solely on its headline capacity.